One scope, one device, one saline bag, no blades.
On-demand aspiration independent of resection.
High-speed, bladeless resection with spot coagulation.
1. Data on File. Internal Memo on Symphion Procedure Steps, Axora Medical.
The Symphion Operative Hysteroscopy System gives physicians the precision and control to remove polyps and fibroids efficiently so intrauterine pathology does not have to wait for a second procedure.
Intuitive Control – Symphion is easy to master—no need to change your side window resection technique. It streamlines the tissue removal process for you and your team. One device. One scope. One saline bag.
Simplified Setup – Contains less components and requires less steps than any other resection system.¹ Each procedure requires just one 3-liter saline bag and no canisters.
OR Efficiency – Optimize the OR with a faster setup, fewer SKUs, less waste, and a simplified procedure, saving valuable time and resources.
1. Data on File. Internal Memo on Symphion Procedure Steps, Axora Medical.
Device details. Reimbursement guides. Clinical studies, social media posts, expert opinions and patient outreach programs. Everything you need in one place.
Yes. Symphion® is indicated for resection of any intrauterine tissue. By design, there is only one Resecting Device size, which is independent of the type and size of pathology for a more streamlined, cost effective, and minimally invasive solution for treatment of AUB due to structural causes.
No, the Symphion system does not use a mechanical blade. It uses bipolar radiofrequency (RF) plasma to resect and coagulate tissue, eliminating the need for a mechanical blade that may dull over time.
Symphion is designed to volumetrically limit the amount of distention media that potentially can be absorbed, and this value will never exceed 2500mL. This is achieved via Symphion’s “closed loop” fluid management system. The re-circulating distention media allows the user to calculate the fluid loss by simply subtracting the remainder of fluid in the 3000mL saline bag from the operating volume of 2500mL. However, an optional fluid deficit readout accessory is available for use with the Symphion Prime controller.
Total Fluid Loss equals 2500mL minus amount of saline remaining in the 3000mL bag (approximately 500mL remains in the system).
No. Symphion uses bladeless RF plasma resection technology. As a result, the Resecting Device does not dull or weaken during treatment.
Symphion has an independent aspiration mode.
Histologic evaluation of the tissue chips indicates a consistent depth of tissue thermal effect limited to ~80 microns.
Symphion helps you treat polyps and fibroids with confidence the first time.
Request a demoSymphion helps you treat polyps and fibroids with confidence the first time.
Request a demo